NVMe_ZNS¶
NVMe_ZNS_23_Finish_Zone.sh¶
ZNS All Zone State ZSIO, ZSEO, ZSC and ZSF to ZSF Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_27_ZoneMgmtSend_ErrorCodes.sh¶
NVMe ZNS Zone Capacity Changed Not Set Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_08_IO_Performance.sh¶
ZNS IO Performance Measurement
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_28_Sanitize.sh¶
NVMe ZNS Sanitize 11 with 1b-11b-Yb-Zb
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_25_Reset_Zone.sh¶
ZNS Zone Descriptor After Reset Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_04_Zone_Descriptor_Extension_Verification.sh¶
NVMe ZNS Zone Descriptor Extension Data Buffer Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_05_Read.sh¶
ZNS Read Test Zone Boundaries
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_00_IdentifyNSIdentDescript.sh¶
NVMe Identify Namespace ID Descriptor command is executed
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_20_Dataset_Write_Hint.sh¶
NVMe ZNS Dataset Write Hint Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_02_State_Transition.sh¶
NVMe ZNS Zone State Transition from ZSC to ZSIO Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_37_Sequential_IO_Matrix_Performance.sh¶
NVMe ZNS Sequential IO Matrix Performance
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_00_GetLogPage.sh¶
NVMe Get Log Page command for each log page ID is executed
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_07_Append.sh¶
NVMe ZNS Append More Than MOR Zone
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_09_Flush.sh¶
NVMe ZNS Flush Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_36_Zone_States_After_Resets.sh¶
NVMe ZNS Zone States Verify After Link Cycle
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_10_Write_Uncorrectable.sh¶
NVMe ZNS Write Uncorrectable Too Many Open Zones Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_11_Compare.sh¶
NVMe ZNS NVM Compare Cross Zone Boundary Test
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_21_Zone_Management_Send.sh¶
ZNS Zone Management Send and Receive with PRPs and SGLs
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_17_Reservation_Report.sh¶
NVMe ZNS Reservation Report Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_38_AsyncEvents.sh¶
NVMe ZNS Async Events No Ack
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_00_IdentifyNamespaceIDs.sh¶
NVMe Identify Namespace IDs command is executed
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_22_Close_Zone.sh¶
ZNS All Zone State ZSIO and ZSEO to ZSC Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_18_Dataset_Deallocate.sh¶
NVMe ZNS Dataset Deallocate Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_16_Reservation_Release.sh¶
NVMe ZNS Reservation Release Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_34_ZoneMgmtRcv_ZRWA.sh¶
NVMe ZNS ZoneMgmtRcv ZRWAA=1 Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_24_Open_Zone.sh¶
ZNS All Zone State ZSC to ZSEO Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_26_Offline_Zone.sh¶
ZNS Zone State ZSE, ZSIO, ZSEO, ZSC and ZSF to ZSO Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_39_IO_WRR_Performance.sh¶
ZNS IO Performance Measurement
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_30_Zone_Management_Receive_Extended_Report.sh¶
NVMe ZNS Zone Management Receive Extended Report Full ZRA=Rsvd Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_33_ZoneMgmtSend_ZRWA.sh¶
NVMe ZNS ZoneMgmtSend ZRWA With Actions Other Than Open Zone
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_40_Copy.sh¶
NVMe ZNS NVM Copy Destination in ZRWA
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_29_Zone_Management_Receive.sh¶
NVMe ZNS Zone Management Receive Full ZRA=Rsvd Verify
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_00_IdentifyController_Decode.sh¶
NVMe Identify Controller command is executed and the output is returned
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_32_IO_Max_Performance.sh¶
ZNS IO Performance Measurement
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_13_Verify.sh¶
NVMe ZNS NVM Verify Cross Zone Boundary Test
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_31_ZRWA_CommitZone.sh¶
NVMe ZNS Commit Zone Explicit Without WP Change
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_01_MAR_MOR_Verify.sh¶
Get Number of Zones With State ZSIO
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_14_Reservation_Register.sh¶
NVMe ZNS Reservation Register Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_12_Write_Zeros.sh¶
NVMe ZNS Write Zeroes More Than MOR Zone
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_00_IdentifyNamespace_Decode.sh¶
NVMe Identify Namespace command is executed and the output is returned
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_06_Write.sh¶
NVMe ZNS Generic Command Status 80h Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_35_ZRWA_Features.sh¶
NVMe ZNS ZRWA Write Cross Zone Boundary
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_15_Reservation_Acquire.sh¶
NVMe ZNS Reservation Acquire Verification
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_03_Identify.sh¶
Identify With Invalid CNS
- Pass/Fail Criteria:
Based on the result of command execution
NVMe_ZNS_19_Dataset_Read_Hint.sh¶
NVMe ZNS Dataset Read Hint Verification
- Pass/Fail Criteria:
Based on the result of command execution